Vernetzungstechnik

Für den Bereich Vernetzungstechnik bietet CONEXIVA Ihnen ein breites Spekttrum an langjährig erprobten Hard- und Softwareprodukten. Unser Sortiment umfasst Gateways zwischen jedem Bus-System, Bus Interfaces sowie Steuergeräte, Produkte zur Restbussimulation, Signalmanipulation, Messdatenerfassung und für Rapid Prototying. 
Benefits
• Complete solution for beginners in automotive bus systems
• FlexRay / CAN / LIN / Ethernet interfaces on the mirco controller platform available
• Functional C-code examples for all interfaces included
• Development toolchain (IDE, Compiler, Debugger) included
• C-code library for all interfaces included
• FlexConfig Developer Demo to configure the FlexRay bus system included
Benefits
• Complete EMC optimized design with best-in-class low emissions
• Best-in-class unsusceptible against noise
• Integrated battery, up to 40 h operation
• Supports WUP and symbols (CAS, MTS, ...)
• Integrated, switchable network termination with power resistors
Benefits
• ARM Cortex A9 dual core (800 MHz) with 1 GByte DDR3 RAM
• 10 bus channels (via pluggable transceivers)
• Up to 7 Ethernet channels
• Up to 10 CAN channels
• Up to 8 FlexRay channels (4 channel A and 4 channel B)
• WiFi and Bluetooth extension available
• Wake-up/sleep mode support
• Startup <200ms possible
• IP67
• Temperature range - 40°C to + 85°C
Benefits
• PowerPC MPC5567 (120 MHz) with 2 MB SRAM
• 5 bus channels (4 via pluggable transceivers)
• Up to 5 CAN channels
• Up to 4 FR channels
• Up to 2 LIN channels
• Wakeup/Sleep mode support
• Startup <100 ms
• Complete development environment included
• PC connection via Ethernet
• IP67
• Temperature range -40°C to +85°C
BENEFITS
• 8x exchangeable bus interfaces
• Physical Layer available for CAN, CAN FD, FlexRay, Ethernet and BroadR-Reach
• Synchronous timestampgeneration for all of the 8 bus interfaces (resolution 1 us)
• PMC-Adapter available for: PCI, PCIe, PXI
• Driver available for: Windows, Linux, LabVIEW
• Numerous triggering capabilities
• Switchable on-board bus termination
• Analysis software included
Benefits
• 1x FlexRay A+B, 2x CAN HS, 1x CAN LS
• Synchronous timestamp generation for all of the bus interfaces
• FlexRay bus system is self-sync capable (second FR-Controller only for synchronization integrated)
• USB powered (no need of an external power supply)
• Numerous triggering capabilities
• Driver available for: Windows, LabVIEW
• Monitoring software included
Vorteile
• Kompaktes Format mit vollem Funktionsumfang
• Zeitstempel mit einer Auflösung von 100µS
• Windows API zur einfachen Einbindung in eigene Applikationen
Vorteile
• LIN-Restbussimulation als PC-Anwendung programmierbar
• Master-Slave-Modus per Software konfigurierbar